Datasheet
Hardware Manual
Web UI User's Manual
For latest firmware, please send request to support@lantechcom.com.au
Lantech IPES-5408T (IP67/IP54) is a high performance L2+ (Gigabit uplink) Ethernet switch with 8 10/100TX(D-coded) + 4 10/100/1000T(X-coded) w/8 PoE 802.3af/at Injectors by M12 provides L2 wire speed and advanced security function for network aggregation deployment. It delivers ITU G.8032 enhanced ring recovery less than 20ms in single ring while also supports train ring, enhanced mode, multiple VLAN mode with easy configuration. The comprehensive QoS, QoS by VLAN, advanced security including INGRESS/EGRESS ACL L2/L3, TACACS+, SSH/SSL, Mac based DHCP server, DHCP Option 82, DHCP server, IGMPv1/v2/v3/router port, QinQ are supported and also required in large network. It also supports Cisco Discovery Protocol (CDP) for Ciscoworks to detect the switch info and show on L2 map topology.
Up to 8 PoE ports with advanced PoE management
Lantech IPES-5408T (IP67/IP54) supports IEEE802.3at/af standard which can feed HI-power up to 30W at each PoE port for big power consumption devices like PTZ IP camera, High power wireless AP etc. The advanced PoE management includes PoE detection and scheduling besides the regular PoE per port status. PoE detection can detect if the connected PD hangs then restart the PD; PoE scheduling is to allow pre-set power feeding schedule upon routine time table. Per port PoE status can remotely On/Off the power and display information of voltage, current, watt and PoE temperature.
Wide selection of input range models (24V/WV) w/maximum PoE budget
The Lantech IPES-5408 is designed with dual power input ranges from 16.8~137.5VDC. The WV model can accept dual 16.8~137.5VDC to feed 54V PoE to provide PoE budget max 80W. 24V model can accept dual 12~56VDC to feed 54V PoE to provide PoE budget max. 80W. Featured with relay contact alarm function, the IPES-5408T is able to connect with alarm system in case of power failure or port disconnection events.
Miss-wiring avoidance, Loop protection, Auto re-powered ring restore
The IPES-5408T (IP67/IP54) also embedded several features for stronger and reliable network protection in an easy and intuitive way. When the pre-set ring configuration failed or looped by miss-wiring, Lantech IPES-5408T (IP67/IP54) is able to alert with the LED indicator and disable ring automatically. Repowered auto ring restore function (node failure protection) ensures the switches in a ring to survive after power breakout is back. The status can be shown in NMS when each switch is back. Loop protection is also available to prevent the generation of broadcast storm when a dumb switch is inserted in a closed loop connection.
DHCP option 82 & Port based, Mac based DHCP, Option66, IPv6 DHCP server**
DHCP server can assign dedicated IP address by MAC or by port (Port based for single switch), it also can assign IP address by port for multiple switches with single DHCP option82 server. For the ending device which need to download file from TFTP server, DHCP Option66 server can offer IP address of TFTP server to DHCP client. Optional IPv6 address resolution for DHCP service can be supported.
User friendly UI, Auto topology drawing, complete CLI
The user friendly UI, innovative auto topology drawing and topology demo makes IPES-5408T (IP67/IP54) much easier to get hands-on. The complete CLI enables professional engineer to configure setting by command line.
Enhanced G.8032 ring; 16 MSTI MSTP; Optional MRP ring
Lantech IPES-5408T (IP67/IP54) features enhanced G.8032 ring which can be self-healed in less than 20ms for single ring topology protection covering Multicast packets. It also supports various ring topologies that covers double ring, multi-chain (under enhanced ring), train ring, basic ring, multiple-VLAN ring and auto-ring by easy setup than others. The innovative auto-Ring configurator (auto mode) can calculate owner and neighbor in one step. It supports MSTP that allows each spanning tree for each VLAN for redundant links with 16 MSTI. Optional MRP (Media Redundancy Protocol) can be supported for industrial automation networks.
QoS by VLAN for legacy devices to tag with priority
QoS by VLAN can allow switch to tag QoS by VLAN regardless the devices acknowledge QoS or not in which greatly enhance the bandwidth management in a network.
QinQ, QoS and GVRP supported
It supports the QinQ, QoS, GVRP for large VLAN segmentation.
IGMPv3, GMRP, router port, static multicast forwarding and multicast Ring protection
The unique multicast protection under enhanced G.8032 ring can offer immediate self-recovery instead of waiting for IGMP table timeout. It also supports IGMPv3, GMRP, router port and static multicast forwarding binding by ports for video surveillance application.
Editable configuration file
Optional N key auto backup, Exported text file
The configuration file of Lantech IPES-5408T (IP67/IP54) can be exported in text file so that it can be edited and configured back to switch with ease for mass deployment. The optional N-key configurator offers firmware upgrade, auto/editable configuration back up and restoration without computer by adjusting the DIP switch.
Event log & message; 1 DI + 1 DO
In case of event, the IPES-5408T (IP67/IP54) is able to send an email** & SMS** text message to pre-defined addresses as well as SNMP Traps out immediately. It provides 1DI and 1DO. When disconnection of the specific port was detected; DO will activate the signal LED to alarm. DI can integrate the sensors for events and DO will trigger the alarm while sending alert information to IP network with email and traps.
Built-in environmental monitoring to show switch inside info
The built-in environmental monitoring can detect switch overall temperature, voltage, total PoE load and current where can send the SNMP traps, email** and SMS** alert when abnormal.
EN50155, EN45545-2, EN61373 verification; High ESD protection
Lantech IPES-5408T (IP67/IP54) features high reliability and robustness coping with extensive EMI/RFI phenomenon, environmental vibration and shocks usually found in factory, substation, steel automation, aviation, mining and process control. It is the best solution for Automation, transportation, surveillance, Wireless backhaul, Semi-conductor factory and assembly lines.
The IPES-5408T (IP67/IP54) is designed to meet with critical network environment with IP67/IP54 aluminum enclosure and M12 connectors for water proof. With EN45545-2 Fire & Smoke, and EN50155 & 61373 verification, the IPES-5408T (IP67/IP54) is best for railway in train/track side, vehicle and mining applications. For more usage flexibilities, IPES-5408T (IP67/IP54) supports wide operating temperature from -40°C to 75°C. IPES-5408T (IP67/IP54) also provides ±2000V EFT and ±6000V ESD contact protection, which can reduce unstable situation caused by power line and Ethernet.
Optional bypass relay prevent from power lost
The optional bypass relay is set to bypass the switch to the next one when power is off in order to protect the network from crashing. Lantech bypass caters to remain in bypass mode until the switch is completely booting up when power is back to avoid another network lost. Smart bypass can be activated when switch encounters power failure or watch dog hang. (IP67 only)
Standards |
IEEE 802.3 10Base-T Ethernet |
||||||
Switch Architecture |
Back-plane (Switching Fabric): 9.6Gbps |
||||||
Transfer Rate |
14,880pps for Ethernet port |
||||||
Mac Address |
16K MAC address table |
||||||
Jumbo frame |
10KB |
||||||
Connectors |
10/100TX: 8 x ports M12 4-pole D-coded with Auto MDI/MDI-X function |
||||||
Network Cable |
10Base-T: 2-pair UTP/STP Cat. 3, 4, 5/ 5E/ 6 cable |
||||||
Bypass Protection** |
Built-in bypass module on uplink ports to pass to next switch in case of power failure (IP67 only) |
||||||
LED |
Per unit: Power 1 (Green), Power 2 (Green), FAULT (Red) |
||||||
DI/DO |
1 Digital Input (DI) : |
||||||
Operating Humidity |
5% ~ 95% (Non-condensing) |
||||||
Operating Temperature |
-40°C~75°C / -40°F~167°F |
||||||
Storage Temperature |
-40°C~85°C / -40°F~185°F |
||||||
Power Supply |
12~56VDC (24V) |
||||||
PoE Budget |
80W |
||||||
PoE pin assignment |
M12 port # 1~ # 8 support IEEE 802.3at/af End-point. Per port provides up to 30W
|
||||||
Power Consumption |
Max. 11W 12V~48VDC input |
||||||
Dimensions |
IP67 model: Aluminum case |
||||||
Weight |
1.4kgs (IP67); 1.8kgs(IP54) |
||||||
Installation |
IP67 model: DIN Rail** and Wall Mount Design |
||||||
EMI & EMS |
FCC Class A, |
||||||
Stability Testing |
EN61373 (Shock and Vibration) |
||||||
MTBF |
685,902 hrs (IEC 62830 standards) |
||||||
Verifications & report |
EN50155/EN50121-3-2/EN50121-4 verification |
||||||
Warranty |
5 years |
Management |
SNMP v1 v2c, v3/ Web/Telnet/CLI |
SNMP MIB |
RFC 1215 Traps MIB* |
ITU G.8032 |
Support ITU G.8032 v2/2012 for Ring protection in less than 20ms for self-heal recovery (basic mode) |
PoE Management |
|
User friendly UI |
Complete CLI for professional setting |
Port Trunk with LACP |
|
LLDP |
Supports LLDP to allow switch to advise its identification and capability on the LAN |
CDP |
Cisco Discovery Protocol for topology mapping |
Environmental Monitoring |
System status for input voltage, current ,total PoE load and ambient temperature to be shown in GUI and sent alerting if any abnormal status |
VLAN |
Port Based VLAN |
IPv6/4 |
Present |
Spanning Tree |
Supports IEEE802.1d Spanning Tree and IEEE802.1w Rapid Spanning Tree, IEEE802.1s Multiple Spanning Tree 16 MSTI |
Quality of Service |
The quality of service determined by port / CoS / ToS / VLAN / 61375-3-4. |
Class of Service |
Support IEEE802.1p class of service, per port provides 8 priority queues |
Login Security |
Supports IEEE802.1X Authentication/RADIUS |
Port Mirror |
Support 3 mirroring types: “RX, TX and Both packet” |
Network Security |
Support 10 IP addresses that have permission to access the switch management and to prevent unauthorized intruder. |
IGMP |
Support IGMP snooping v1,v2,v3; 1024 multicast groups; IGMP router port ; IGMP query; GMRP** |
Static MAC-Port bridge |
Static multicast forwarding forward reversed IGMP flow with multicast packets binding with ports for IP surveillance application |
Bandwidth Control |
Support ingress packet filter and egress packet limit. |
Flow Control |
Supports Flow Control for Full-duplex and Back Pressure for Half-duplex |
System Log |
Supports System log record and remote system log server |
SMTP/Text SMS** |
Supports SMTP Server and 8 e-mail** accounts for receiving event alert; can send SMS** text alert via mobile |
Relay Alarm |
Provides one relay output for port breakdown, power fail and alarm. |
Protection |
Loop protection |
SNMP Trap |
Up to 10 trap stations; trap types including:
|
DHCP |
Provide DHCP Client/ DHCP Server/DHCP Option 82/Port based DHCP; DHCP Option 66; IPv6 address resolution for DHCP server** |
Mac based DHCP Server |
Assign IP address by Mac. |
DNS |
Provide DNS client feature. |
SNTP |
Supports SNTP to synchronize system clock in Internet |
Firmware Update |
Supports TFTP/SFTP** firmware update, TFTP backup and restore; HTTP firmware upgrade |
N-Key Configurator** |
RJ45 dongle for firmware upgrade, auto / editable configuration backup/restoration |
Configuration |
Supports editable configuration file for system quick installation; |
IP67 model
IP54 model
P/N | Model name | Description |
---|---|---|
8360-6049 | IPES-5408T-67-24V | 8 10/100TX PoE at/af up to 30W + 4 10/100/1000T X-coded EN50155 M12 IP67 L2+ Managed Ethernet Switch; -40°C to 75°C; 12V~56V dual input |
8360-6024 | IPES-5408T-54-24V | 8 10/100TX PoE at/af up to 30W + 4 10/100/1000T X-coded EN50155 M12 IP54 L2+ Managed Ethernet Switch; -40°C to 75°C; 12V~56V dual input |
8360-6039 | IPES-5408T-67-WV | 8 10/100TX PoE at/af up to 30W + 4 10/100/1000T X-coded EN50155 M12 IP67 L2+ Managed Ethernet Switch; -40°C to 75°C; 16.8~137.5V dual input |
8360-6020 | IPES-5408T-X-54-WV | 8 10/100TX PoE at/af up to 30W + 4 10/100/1000T X-coded EN50155 M12 IP54 L2+ Managed Ethernet Switch; -40°C to 75°C; 16.8~137.5V dual input |
8850-100 | N-key Configurator | RJ45 connector dongle for firmware upgrade, auto/editable configuration backup and restoration; -20°C to 60° |
Model name | Description |
---|---|
ECONM12-5P(F)70CM CABLE | 5 pin M12 power cable 90 degree angle, 70cm |
ECONM12-4P(F)1.5M CABLE | 4 pin M12 power cable 90 degree angle, 150cm |
ECONM12-04A(F)-C-180 | M12 4P(Female) A-coded 180 Degree Crimp Type Connector |
ECONM12-5P(M)-W-180 | M12 5P(Male) 180 Degree Wire Type Connector (DI/DO) |
ECONM12-04D(M)-C-180 | Connector,4-pin (Male),M12 D-coded Crimp Type 180 degree |
ECAB124030MJS | 4 Pin M12 RJ45 Male 3 Meters; STP Cable |
Lantech USB Dongle | M12 to USB 2.0 dongle |
2020 © Lantech Communications Australia Pty Ltd. ALL Rights Reserved. Privacy Policy | Terms of Service