Lantech IPGS-5424 is a high performance L2 + PoE managed industrial switch which provides L2 wire speed and advanced security function for network aggregation and backbone deployment. It delivers ITU G.8032 enhanced ring recovery less than 20ms including dynamic coupling ring, and enhanced mode for easy configuration, comprehensive QoS, QoS by VLAN, advanced security including INGRESS/EGRESS ACL L2/L3, SSH/SSL, Mac based DHCP server, DHCP Option 82, DHCP server, IGMPv1/v2/v3/router port, QinQ* (double tag VLAN) which are important features required in train and large network. It also supports Cisco Discovery Protocol (CDP) and LLDP for Ciscoworks to detect the switch info and show on L2 map topology.
Compliant with 802.3af/at standard, the Lantech IPGS-5424 is able to feed each PoE port up to 30 Watts@54 VDC providing the connected PD devices. Lantech IPGS-5424 supports advanced PoE management including PoE detection and scheduling. PoE detection can detect if the connected PD hangs then restart the PD; PoE scheduling is to allow pre-set power feeding schedule upon routine time table. Each PoE ports can be Enabled/disabled, get the voltage, current, Watt, and temperature info displayed on WebUI.
The IPGS-5424 also embedded several features for stronger and reliable network protection in an easy and intuitive way. When the pre-set ring configuration failed or looped by miss-wiring, Lantech IPGS-5424 is able to alert with the LED indicator and send out an email, traps or a SMS text. Repowered auto ring restore function (node failure protection) ensures the switches in a ring to survive after power breakout is back. The status can be shown in NMS when each switch is back. This feature prevents the broken ring and keep ring alive without any re-configuration needed. Loop protection is also available to prevent the generation of broadcast storm when a dumb switch is inserted in a closed loop connection.
DHCP server can assign dedicated IP address by MAC or by port (Port based for single switch) , it also can assign IP address by port for multiple switches with single DHCP option82 server. DHCP Option66 server can offer IP address of TFTP server to DHCP client for VOIP application. Optional IPv6 address resolution for DHCP service can be supported.
The user friendly UI, innovative auto topology drawing and topology demo makes IPGS-5424 much easier to get hands-on. The switch also equips the RTC (real time clock) which can keep track of time always. The IPGS-5424 supports DMI interface that can correspond with DDM SFPs (Digital diagnostic monitor) to display the five parameters in Lantech’s UI, including optical output power, input power, temperature, laser bias current and transceiver supply voltage***. The TX power/RX power raw data is automatically converted to dB values for installer, making it easier to calculate the fiber distance. The complete CLI enables professional engineer to configure setting by command line.
Lantech IPGS-5424 features enhanced G.8032 ring which can be self-healed in less than 20ms for single ring topology protection covering Multicast packets. It also supports various ring topologies that covers double ring, multi-chain (under enhanced ring), train ring, basic ring by easy setup than others. The innovative auto-Ring configurator (auto mode) can calculate owner and neighbor in one step. It supports MSTP that allows RSTP over Vlan for redundant links with 8/16* MSTI.
The configuration file of Lantech IPGS-5424 can be exported in text file so that it can be edited and configured back to switch with ease for mass deployment. The factory reset button can restore the setting back to factory default and built-in watchdog design can automatically reboot the switch when CPU is found dead. The USB slot allows user to backup/ restore configuration.
QoS by VLAN can allow switch to tag QoS by VLAN regardless the devices acknowledge QoS or not in which greatly enhance the bandwidth management in a network.
The IPGS-5424 DIDO function can support additional open/close physical contact for designate applications besides Port / Power events, for example, DIDO function can trigger alarm if the switch was moved or stolen. In case of events, the IPGS-5424 will immediately send an email & SMS text message to pre-defined addresses as well as SNMP Traps out. It provides 2DI and 2DO while disconnection of the specific port was detected; DO will activate the signal LED to alarm. DI can integrate the sensors for events and DO will trigger the alarm while sending alert information to IP network with email and traps.
The built-in environmental monitoring can detect switch overall temperature, voltage and current where can send the SNMP traps, email and SMS alert when abnormal.
The Lantech IPGS-5424 is designed with dual power supply at 12/24/48VDC or 85~265VAC. Featured with relay contact alarm function, the IPGS-5424 is able to connect with alarm system in case of power failure. The IPGS-5424 also provides ±4000V EFT and ±8000V ESD protection, which can reduce unstable situation caused by power line and Ethernet.
Lantech IPGS-5424 features high reliability and robustness coping with extensive EMI/RFI phenomenon, environmental vibration and shocks usually found in factory, substation, steel automation, aviation, mining and process control. It is the best solution for Automation, transportation, surveillance, Wireless backhaul, Semi-conductor factory and assembly lines.
The IPGS-5424-E can be used in extreme environments with an operating temperature range of -40°C to 75°C.
IEEE Standards |
IEEE 802.3 10Base-T Ethernet |
||||||
Switch Architecture |
Back-plane (Switching Fabric): 56Gbps |
||||||
Transfer Rate |
14,880pps for Ethernet port |
||||||
CPU |
Marvell 800Mhz |
||||||
RAM |
256M Byte |
||||||
Flash |
128M Byte |
||||||
Mac Address |
16K MAC address table |
||||||
Jumbo frame |
10KB* |
||||||
PoE pin assignment |
RJ-45 port # 1~# 24 support PoE at/af End-point, |
||||||
PoE input voltage & Power feed voltage |
|
||||||
Connectors |
24 10/100/1000T RJ-45 with auto MDI/MDI-X function |
||||||
DDM |
Conform to SFF-8472 to show diagnostic SFP with temperature, current, voltage, input and output power |
||||||
Protocol |
CSMA/CD |
||||||
LED |
Per unit: Power 1 (Green), Power 2 (Green), Fault (Red) ,R.M (Green) |
||||||
Power Supply |
AC model: 85~265V AC IEC320 conversion X1 DC model: 12~56VDC INPUT X1 PoE power: dual input for 45~57VDC Additional power socket (optional):
|
||||||
Power Consumption |
Full load: 30W/ Unload: 13W |
||||||
PoE Power Budget |
720W |
||||||
Relay Alarm |
Provides one relay output for port breakdown, power fail and alarm. |
||||||
DI/DO |
2 Digital Input (DI) : |
||||||
Case Dimension |
19” Metal case,IP-30; 440mm(W)x325mm(D)x44mm(H) |
||||||
Operating Humidity |
5%~95% (Non-condensing) |
||||||
Operating Temperature |
Standard: -20°C ~60°C |
||||||
Storage Temperature |
-40°C ~85°C |
||||||
EMI |
FCC Class A, CE EN61000-4-2 (ESD), |
||||||
Stability Testing |
IEC60068-2-32 (Free fall), IEC60068-2-27 (Shock), IEC60068-2-6 (Vibration) |
||||||
MTBF |
586,450 hours |
||||||
Warranty |
5 years |
Management |
SNMP v1 v2c, v3/ Web/Telnet/CLI |
SNMP MIB |
RFC 1215 Traps MIB, |
ITU G.8032 |
Support ITU G.8032 v2/2012 for Ring protection in less than 20ms for self-heal recovery (basic mode) |
PoE Management |
|
User friendly UI |
|
Port Trunk with LACP |
LACP Port Trunk: 8 Trunk groups/Maximum 24 trunk members |
LLDP |
Supports LLDP to allow switch to advise its identification and capability on the LAN |
CDP |
Cisco Discovery Protocol for topology mapping |
Environmental Monitoring |
System status for input voltage, current and ambient temperature to be shown in GUI and sent alerting if any abnormal status |
VLAN |
Port Based VLAN |
IPv6/4 |
Present |
Spanning Tree |
Supports IEEE802.1d Spanning Tree and IEEE802.1w Rapid Spanning Tree, IEEE802.1s Multiple Spanning Tree |
Quality of Service |
The quality of service determined by port, Tag and IPv4 Type of service, IPv4 Differentiated Services Code Points - DSCP |
Class of Service |
Support IEEE802.1p class of service, per port provides 8 priority queues |
QoS by VLAN |
Tagged QoS by VLAN for all devices in the network |
Login Security |
Supports IEEE802.1X Authentication/RADIUS |
Port Mirror |
Support 3 mirroring types: “RX, TX and Both packet” |
Network Security |
Support 10 IP addresses that have permission to access the switch management and to prevent unauthorized intruder. |
IGMP |
Support IGMP snooping v1,v2,v3; 1024 multicast groups; IGMP router port ; IGMP query; GMRP* |
Static MAC-Port bridge |
Static multicast forwarding forward reversed IGMP flow with multicast packets binding with ports for IP surveillance application |
Bandwidth Control |
Support ingress packet filter and egress packet limit. |
RTC |
Built-in Real Time Clock to keep track of time always |
Flow Control |
Supports Flow Control for Full-duplex and Back Pressure for Half-duplex |
System Log |
Supports System log record and remote system log server |
SMTP/Text SMS |
Supports SMTP Server and 8 e-mail accounts for receiving event alert; can send SMS text alert via mobile |
Relay Alarm |
Provides one relay output for port breakdown, power fail and alarm. |
Protection |
|
SNMP Trap |
Up to 10 trap stations; trap types including:
|
DHCP |
Provide DHCP Client/ DHCP Server/DHCP Option 82/Port based&VLAN based DHCP distribution (DHCP relay agent) |
Mac based DHCP Server |
Assign IP address by Mac that can include dumb switch in DHCP network |
DNS |
Provide DNS client feature and support Primary and Secondary DNS server. |
SNTP |
Supports SNTP to synchronize system clock in Internet |
Firmware Update |
Supports TFTP firmware update, TFTP backup and restore; HTTP firmware upgrade |
Configuration |
Supports text configuration file for system quick installation; Support factory reset button to restore all settings back to factory default; USB for edited restoration and auto backup |
IfAlias |
Each port allows an alphabetic string of 128-byte assigned as its own unique name via the SNMP or CLI interface |
P/N | Model name | Description |
---|---|---|
8380-601 | IPGS-5424-DC | 24 10/100/1000T PoE at/af + 4 Dual SFP L2 plus Industrial Switch Built-in 1x 12~56V DC + 1x additional power socket; -20°C to 60°C |
8380-600 | IPGS-5424-AC | 24 10/100/1000T PoE at/af + 4 Dual SFP L2 plus Industrial Switch Built-in 1x 85~265V AC IEC320 conversion + 1x additional power socket; -20°C to 60°C |
8380-6011 | IPGS-5424-DC-E | 24 10/100/1000T PoE at/af + 4 Dual SFP L2 plus Industrial Switch Built-in 1x 12~56V DC + 1x additional power socket; -40°C to 75°C |
8380-6001 | IPGS-5424-AC-E | 24 10/100/1000T PoE at/af + 4 Dual SFP L2 plus Industrial Switch Built-in 1x 85~265V AC IEC320 conversion + 1x additional power socket; -40°C to 75°C |
Model name | Description |
---|---|
EOTH000701 | Isolation Power 85-265VAC, 100-370VDC 1.5A, 47-63HZ![]() |
EOTH000702 | Isolation Power 36-75VDC, 2.5A![]() |
EOTH000703 | Power 85-264VAC IEC320 socket, 1.5A , 47-63HZ![]() |
EOTH000704 | Power Input Module 12-57VDC, 2.5A![]() |
Model name | Description |
---|---|
NDR-480 Series | 480W Single Output Industrial Din Rail Power; 90-264VAC / 127-370VDC Input Range; Cooling by free air convection; RoHS2 ; Operating Temp. -20°C~70°C (ambient, derating each output at 2.5% per degree from 50°C ~ 70°C) |
NDR-240 Series | 240W Single Output Industrial Din Rail Power; 90-264VAC / 127-370VDC Input Range; Cooling by free air convection; RoHS2 ; Operating Temp. -20°C~70°C (ambient, derating each output at 2.5% per degree from 50°C ~ 70°C) |
NDR-120 Series | 120W Single Output Industrial Din Rail Power; 90-264VAC / 127-370VDC Input Range; Cooling by free air convection; RoHS2 ; Operating Temp. -20°C~70°C (ambient, derating each output at 2.5% per degree from 50°C ~ 70°C; For 115VAC, please refer to derating curve on NDR-120 Series datasheet) |
NDR-75 Series | 75W Single Output Industrial Din Rail Power; 90-264VAC / 127-370VDC Input Range; Cooling by free air convection; RoHS2 ; Operating Temp. -20°C~70°C (ambient, derating each output at 2.5% per degree from 50°C ~ 70°C; For 115VAC, please refer to derating curve on NDR-120 Series datasheet) |
Model name | Description | Model name | Description |
---|---|---|---|
8330-162-V1 | MINI GBIC 1000SX (LC/0.5KM) Transceiver | 8330-187-V1 | LTSFP-1000BX-20KM Transceiver (WDM 1550) |
8330-163-V1 | MINI GBIC 1000SX2 (LC/2KM) Transceiver | 8330-180-V1 | LTSFP-1000BX-40KM Transceiver (WDM 1310) |
8330-165-V1 | MINI GBIC 1000LX (LC/10KM) Transceiver | 8330-182-V1 | LTSFP-1000BX-40KM Transceiver (WDM 1550) |
8340-0591-V1 | MINI GBIC 1000LHX (LC/40KM) Transceiver | 8330-181-V1 | LTSFP-1000BX-60KM Transceiver (WDM 1310) |
8330-166-V1 | MINI GBIC 1000XD (LC/50KM) Transceiver | 8330-183-V1 | LTSFP-1000BX-60KM Transceiver (WDM 1550) |
8330-169-V1 | MINI GBIC 1000XD (LC/60KM) Transceiver | 8330-184-V1 | LTSFP-1000BX-80KM Transceiver (WDM 1490) |
8330-167-V1 | MINI GBIC 1000ZX (LC/80KM) Transceiver | 8330-185-V1 | LTSFP-1000BX-80KM Transceiver (WDM 1550) |
8330-170-V1 | MINI GBIC 1000EZX (120KM) Transceiver | 8330-071-V1 | 125Mbps BiDi SFP 2KM (WDM 1310) Transceiver |
8330-168-V1 | MINI GBIC 10/100/1000T (100m) Transceiver | 8330-072-V1 | 125Mbps BiDi SFP 2KM (WDM 1550) Transceiver |
8330-060-V1 | 100Base FX 2KM, Multi-mode, LC Transceiver | 8330-069-V1 | 125Mbps BiDi SFP 20KM (WDM 1310) Transceiver |
8330-065-V1 | 100Base FX 5KM, Multi-mode, LC Transceiver | 8330-068-V1 | 125Mbps BiDi SFP 20KM (WDM 1550) Transceiver |
8330-061-V1 | 100Base LX 30KM, Single-mode, LC Transceiver | 8330-080 | 125Mbps BiDi SFP 40KM (WDM 1310) Transceiver |
8330-197-V1 | 1.25Gbps BiDi SFP 0.5KM Transceiver (WDM 1310) | 8330-082 | 125Mbps BiDi SFP 40KM (WDM 1550) Transceiver |
8330-198-V1 | 1.25Gbps BiDi SFP 0.5KM Transceiver (WDM 1550) | 8330-081 | 125Mbps BiDi SFP 60KM (WDM 1310) Transceiver |
8330-195-V1 | 1.25Gbps BiDi SFP 2KM Transceiver (WDM 1310) | 8330-083 | 125Mbps BiDi SFP 60KM (WDM 1550) Transceiver |
8330-196-V1 | 1.25Gbps BiDi SFP 2KM Transceiver (WDM 1550) | 8330-084 | 125Mbps BiDi SFP 80KM (WDM 1310) Transceiver |
8330-188-V1 | 1.25Gbps BiDi SFP 10KM Transceiver (WDM 1310) | 8330-085 | 125Mbps BiDi SFP 80KM (WDM 1550) Transceiver |
8330-189-V1 | 1.25Gbps BiDi SFP 10KM Transceiver (WDM 1550) | 8330-191-V1 | Dual Speed SFP 100M/1000M-LX 10KM Transceiver |
8330-186-V1 | 1.25Gbps BiDi SFP 20KM Transceiver (WDM 1310) | All SFP P/N# ended with D are with DDM function |
2020 © Lantech Communications Australia Pty Ltd. ALL Rights Reserved. Privacy Policy | Terms of Service