Datasheet
Hardware Manual
For latest firmware and web UI user manual, please send request to support@lantechcom.com.au
Lantech IPGS-5488MGSFP is a high performance L2+ (All Gigabit) Ethernet switch with 8 10/100/1000T + 8 100M/1G SFP + 4 1G/2.5G SFP auto-sensing cage w/8 PoE 802.3 af/at ports which provides L2 wire speed and advanced security function for network aggregation deployment. It delivers ITU G.8032 enhanced ring recovery less than 20ms in single ring. It also supports enhanced mode with easy configuration, comprehensive QoS, QoS by VLAN**, advanced security including INGRESS ACL L2/L3, TACACS+, SSH v2/SSL, Mac based DHCP server, DHCP Option 82, DHCP server, IGMPv1/v2/v3/router port, QinQ which are important features required in large network. The Cisco Discovery Protocol (CDP) and LLDP are supported for Ciscoworks to detect the switch info and show on L2 map topology. The enhanced platform allows quick booting up time under 50 seconds.
PoE at/af up to 8 10/100TX Ports with detection and scheduling
Compliant with 802.3af/at standard, the Lantech IPGS-5488MGSFP is able to feed each PoE port up to 30 watt. Lantech IPGS-5488MGSFP supports advanced PoE management including PoE detection and scheduling. PoE detection can detect if the connected PD is hanged then restart the PD; PoE scheduling is to allow pre-set power feeding schedule upon routine time table. Each PoE port can be enabled/disabled, get the voltage, current, Watt, and temperature info displayed on WebUI.
Miss-wiring avoidance, Loop protection, Node failure protection
The IPGS-5488MGSFP also embedded several features for stronger and reliable network protection in an easy and intuitive way. When the pre-set ring configuration failed or looped by miss-wiring, Lantech IPGS-5488MGSFP is able to alert with the LED indicator and disable ring automatically. Node failure protection ensures the switches in a ring to survive after power breakout is back. The status can be shown in NMS when each switch is back. This feature prevents the broken ring and keep ring alive without any re-configuration needed. Loop protection is also available to prevent the generation of broadcast storm when a dumb switch is inserted in a closed loop connection.
DHCP option 82 & Port based, Mac based DHCP, Option66, IPv6 DHCP server
DHCP server can assign dedicated IP address by MAC or by port (Port based for single switch) , it also can assign IP address by port for multiple switches with single DHCP option82 server. For the ending device which need to download file from TFTP server, DHCP Option66 server can offer IP address of TFTP server to DHCP client. Basic IPv6 DHCP service can be supported.
User friendly GUI, Auto topology drawing
The user-friendly UI, innovative auto topology drawing and topology demo makes IPGS-5488MGSFP much easier to get hands-on. The complete CLI enables professional engineer to configure setting by command line.
Enhanced G.8032 ring, 8 MSTI MSTP; MRP ring
Lantech IPGS-5488MGSFP features enhanced G.8032 ring which can be self-healed in less than 20ms for single ring topology protection covering multicast packets. It also supports various ring topologies that covers enhanced ring and basic ring by easy setup than others. It supports MSTP that allows RSTP over VLAN for redundant links with 8 MSTI. MRP (Media Redundancy Protocol) can be supported for industrial automation networks.
QinQ, QoS and GVRP supported
It supports the QinQ, QoS, GVRP for large VLAN segmentation.
IGMPv3, GMRP, router port, MLD Snooping, static multicast forwarding and multicast Ring protection
The unique multicast protection under enhanced G.8032 ring can offer immediate self-recovery instead of waiting for IGMP table timeout. It also supports IGMPv3, GMRP, router port, MLD Snooping and static multicast forwarding binding by ports for video surveillance application.
Enhanced Storm Control
Storm control prevents traffic on a LAN from being disrupted by a broadcast, multicast, or unicast storm on one of the physical interfaces and the detection is more precise and reaction is more efficient.
Optional L3Lite/L3 to be upgradable
Lantech OS3 is optional upgradable to L3 Lite for future expansion. The optional L3Lite includes editable routing table, VRRP, Router-on-a-stick, Inter- VLAN routing.
Editable configuration file; USB port for upload/download configuration
The configuration file of Lantech IPGS-5488MGSFP can be exported and edited with word processor for the other Ethernet switches configuration with ease. The built-in watchdog design can automatically reboot the switch when CPU is found dead. The USB port can upload/download the configuration from/to USB dongle.
2DI/2DO for relay contact and event alerting by email** traps
In case of event, the IPGS-5488MGSFP is able to send an email to pre-defined addresses as well as SNMP Traps out immediately. It provides 2DI and 2DO. When disconnection of the specific port was detected; DO will activate the signal LED to alarm. DI can integrate the sensors for events and DO will trigger the alarm while sending alert information to IP network with email and traps.
Enhanced Environmental monitoring for Ethernet switch inside information
The enhanced environmental monitoring can detect switch overall temperature, actual input voltage and current. It also can send the SNMP traps and email** when abnormal.
Dual power 24V or 48V input; High PoE budget
The Lantech IPGS-5488MGSFP is designed with dual power supply at 12VDC (24V model) for 12V~56VDC input and can provide 80W (12V input) or 120W (24V input) PoE budget. The 48V model can support dual power 44VDC~56VDC input and can have 240W PoE budget.
Industrial hardened design with high EFT and ESD protection
Lantech IPGS-5488MGSFP features high reliability and robustness coping with extensive EMI/RFI phenomenon, environmental vibration and shocks usually found in factory, substation, steel automation, aviation, mining and process control. Featured with relay contact alarm function, the IPGS-5488MGSFP is able to connect with alarm system in case of power failure or port disconnection. The IPGS-5488MGSFP also provides ±2000V EFT and ±6000V ESD protection, which can reduce unstable situation caused by power line and Ethernet.
It is the best solution for Automation, transportation, surveillance, Wireless backhaul, Semi-conductor factory applications. The -E model can be used in extreme environments with an operating temperature range of -40°C to 75°C
Standards |
IEEE802.3 10Base-T Ethernet |
Switch Architecture |
Back-plane (Switching Fabric): 52Gbps |
Mac Address |
16K MAC address table |
Jumbo frame |
10KB |
Connectors |
10/100/1000T: 8 x ports RJ-45 with Auto MDI/MDI-X function |
Network Cable |
10Base-T: 2-pair UTP/STP Cat. 3, 4, 5/ 5E/ 6 cable |
Optical Cable |
1Gbps: |
LED |
Per unit: Power 1 (Green), Power 2 (Green), FAULT (Red); RM(Green) |
DI/DO |
2 Digital Input (DI) : |
Operating Humidity |
5% ~ 95% (Non-condensing) |
Operating Temperature |
-20°C~60°C / -4°F~140°F (Standard model) |
Storage Temperature |
-40°C~85°C / -40°F~185°F |
Power Supply |
Dual 12~56VDC (24V model); |
PoE Budget |
24V model: 24V: 120W / 12V: 80W |
PoE pin assignment |
RJ-45 port # 1~#8 support IEEE 802.3at/af End-point, Alternative A mode. |
Power Consumption |
25W without PoE load |
Case Dimension |
Metal case. IP-30, |
Weight |
900 g |
Installation |
DIN Rail and Wall Mount** Design |
EMI & EMS |
FCC Class A, |
Stability Testing |
IEC60068-2-32 (Free fall), IEC60068-2-27 (Shock), |
MTBF |
591,245 (Hrs) |
Warranty |
5 years |
Management |
SNMP v1 v2c, v3/ Web/Telnet/CLI |
SNMP MIB |
RFC 1213 MIBII |
PoE Management |
PoE Detection to check if PD hangs then restart the PD |
Per Port PoE Status |
On/ Off, voltage, current, watts, temperature |
ITU G.8032 |
Support ITU G.8032 for Ring protection in less than 20ms for self-heal recovery (single ring enhanced mode) |
User friendly UI |
|
Port Trunk with LACP |
LACP Port Trunk: 10 Trunk groups |
LLDP |
Supports LLDP to allow switch to advise its identification and capability on the LAN |
CDP |
Cisco Discovery Protocol for topology mapping |
Enhanced Environmental Monitoring |
System status for actual input voltage, current, total power load and ambient temperature to be shown in GUI and sent alerting if any abnormal status |
VLAN |
Port Based VLAN |
Spanning Tree |
Supports IEEE802.1d Spanning Tree** and IEEE802.1w Rapid Spanning Tree, IEEE802.1s Multiple Spanning Tree 8 MSTI |
Quality of Service |
The quality of service determined by IPv4 Type of service, IPv4 Differentiated Services Code Points - DSCP |
Class of Service |
Support IEEE802.1p class of service, per port provides 8 priority queues |
Remote Admin |
Supports 10 IP addresses that have permission to access the switch management and to prevent unauthorized intruder |
Login Security |
Supports IEEE802.1X Authentication/RADIUS |
Port Mirror |
Support 3 mirroring types: “RX, TX and Both packet” |
Network Security |
Support 10 IP addresses that have permission to access the switch management and to prevent unauthorized intruder. |
MLD Snooping |
Support IPv6 Multicast stream |
IGMP |
Support IGMP snooping v1,v2,v3; 256 multicast groups; IGMP router port ; IGMP query; GMRP |
Static multicast forwarding |
Static multicast forwarding forward reversed IGMP flow with multicast packets binding with ports for IP surveillance application |
Bandwidth Control |
Support ingress packet filter and egress* packet limit. |
Flow Control |
Supports Flow Control for Full-duplex and Back Pressure for Half-duplex |
System Log |
Supports System log record and remote system log server |
SMTP |
Supports SMTP Server and 8 e-mail accounts for receiving event alert |
Relay Alarm |
Provides one relay output for port breakdown, power fail and alarm. |
Protection |
|
SNMP Trap |
Up to 5 trap stations; trap types including:
|
PXE |
PXE to verify switch firmware with the latest or certain version |
DHCP |
Provide DHCP Client/ DHCP Server/DHCP Option 82/Port based DHCP; DHCP Option 66; basic IPv6 DHCP server |
Mac based DHCP |
Assign IP address by Mac that can include dumb switch in DHCP network |
DNS |
Provide DNS client feature and can set Primary and Secondary DNS server |
SNTP |
Supports SNTP to synchronize system clock in Internet |
Firmware Update |
Supports TFTP firmware update, TFTP backup and restore; HTTP firmware upgrade |
Optional L3Lite/L3* |
Lantech OS3 is optional upgradable to L3 Lite/L3* for future expansion. The optional L3Lite includes editable routing table, VRRP, Router-on-a-stick, Inter- VLAN routing. |
Configuration |
Supports text configuration file for system quick installation; |
Diagnostic |
Support Ping, ARP table and DDM information |
Dual Image Firmware |
Support dual image firmware function |
P/N | Model name | Description |
---|---|---|
8350-855 | IPGS-5488MGSFP-48V | 8 10/100/1000T PoE at/af up to 30W + 8 100M/1G SFP + 4 1G/2.5G SFP L2+ Industrial PoE Managed Ethernet Switch; -20°C to 60°C; Enhanced Environmental Monitoring; dual 44V~56V input, PoE budget 240W |
8350-8551 | IPGS-5488MGSFP-48V-E | 8 10/100/1000T PoE at/af up to 30W + 8 100M/1G SFP + 4 1G/2.5G SFP L2+ Industrial PoE Managed Ethernet Switch; -40°C to 75°C; Enhanced Environmental Monitoring; dual 44V~56V input, PoE budget 240W |
8350-856 | IPGS-5488MGSFP-24V | 8 10/100/1000T + 8 100M/1G SFP + 4 1G/2.5G SFP L2+ Industrial PoE Managed Ethernet Switch; -20°C to 60°C; Enhanced Environmental Monitoring; dual 12V~56VDC input, PoE budget 80W at 12V; 120W at 24V |
8350-8561 | IPGS-5488MGSFP-24V-E | 8 10/100/1000T + 8 100M/1G SFP + 4 1G/2.5G SFP L2+ Industrial PoE Managed Ethernet Switch; -40°C to 75°C; Enhanced Environmental Monitoring; dual 12V~56VDC input, PoE budget 80W at 12V; 120W at 24V |
P/N | Model name | Description |
---|---|---|
9000-114 | OS3 – L3L | OS3 software platform with Layer 3 Lite functions (please check Lantech software data sheet for details) |
9000-116 | OS3 – L3* | OS3 software platform with Layer 3 functions incl. L3L (please check Lantech software data sheet for details) |
Model name | Description |
---|---|
NDR-240-48 | 240W (48V 5A) Single Output Industrial Din Rail Power; 90-264VAC / 127-370VDC Input Range; Cooling by free air convection; RoHS2 ; Operating Temp. -20°C~70°C (ambient, derating each output at 2.5% per degree from 50°C ~ 70°C) |
NDR-120-48 | 120W (48V 2.5A) Single Output Industrial Din Rail Power; 90-264VAC / 127-370VDC Input Range; Cooling by free air convection; RoHS2 ; Operating Temp. -20°C~70°C (ambient, derating each output at 2.5% per degree from 50°C ~ 70°C; For 115VAC, please refer to derating curve on NDR-120 Series datasheet) |
Model name | Description | Model name | Description |
---|---|---|---|
8330-162X | MINI GBIC 1000SX (LC/0.5km) Transceiver | 8330-186 | LTSFP-1000BX-20KM Transceiver (WDM 1310) |
8330-163X | MINI GBIC 1000SX2 (LC/2km) Transceiver | 8330-187 | LTSFP-1000BX-20KM Transceiver (WDM 1550) |
8330-165X | MINI GBIC 1000LX (LC/10km) Transceiver | 8330-180 | LTSFP-1000BX-40KM Transceiver (WDM 1310) |
8340-0591 | MINI GBIC 1000LHX (LC/40km) Transceiver | 8330-182 | LTSFP-1000BX-40KM Transceiver (WDM 1550) |
8330-166 | MINI GBIC 1000XD (LC/50km) Transceiver | 8330-181 | LTSFP-1000BX-60KM Transceiver (WDM 1310) |
8330-169 | MINI GBIC 1000XD (LC/60km) Transceiver | 8330-183 | LTSFP-1000BX-60KM Transceiver (WDM 1550) |
8330-167 | MINI GBIC 1000ZX (LC/80km) Transceiver | 8330-184 | LTSFP-1000BX-80KM Transceiver (WDM 1490) |
8330-170 | MINI GBIC 1000EZX (120km) Transceiver | 8330-185 | LTSFP-1000BX-80KM Transceiver (WDM 1550) |
8330-168 | MINI GBIC 1000T (100m) Transceiver | 8330-262D | MINI GBIC 2.5G 850nm VCSEL (LC/0.3km) Transceiver |
8330-188 | LTSFP-1000BX-10KM Transceiver (WDM 1310) | 8330-263D | MINI GBIC 2.5G 1310nm FP (LC/2km) Transceiver |
8330-189 | LTSFP-1000BX-10KM Transceiver (WDM 1550) | 8330-265D | MINI GBIC 2.5G 1310nm DFB (LC/15km) Transceiver |
All SFP P/N# ended with D are with DDM function |
2020 © Lantech Communications Australia Pty Ltd. ALL Rights Reserved. Privacy Policy | Terms of Service