Datasheet
Hardware Manual
For latest firmware and web UI user manual, please send request to support@lantechcom.tw
Lantech I(P)GS-6300-2P is a high performance L2+ (All Gigabit) modular Ethernet switch with max 24/26port Gigabit + 4 10G uplink (total 28ports) w/(24 PoE 802.3af/at ports) which provides L2+ wire speed and advanced security function for network aggregation deployment. It delivers ITU G.8032 enhanced ring recovery less than 20ms in single ring. The QoS, advanced security including INGRESS ACL L2/L3, TACACS+, SSH v2/SSL and subnet VLAN, protocol VLAN and Mac based DHCP server, DHCP Option 82, DHCP server, IGMPv1/v2/v3/router port are supported and also required in large network. It also supports 10K Jumbo frames.
Up to 24 PoE at/af ports w/advanced PoE management
Compliant with 802.3af/at standard, the Lantech I(P)GS-6300-2P is able to feed each PoE port up to 30
Watt. Lantech I(P)GS-6300-2P supports advanced PoE management including PoE detection and scheduling. PoE
detection can detect if the connected PD hangs then restart the PD; PoE scheduling is to allow pre-set
power feeding schedule upon routine time table. Each PoE port can be enabled/disabled, get the voltage,
current, Watt, and temperature info displayed on WebUI.
Miss-wiring avoidance, Loop protection, Node failure protection
The I(P)GS-6300-2P also embedded several features for stronger and reliable network protection in an easy and intuitive way. When the pre-set ring configuration failed or looped by miss-wiring, Lantech I(P)GS-6300-2P is able to alert with the LED indicator and disable ring automatically. Node failure protection ensures the switches in a ring to survive after power breakout is back. The status can be shown in NMS when each switch is back. This feature prevents the broken ring and keep ring alive without any re-configuration needed. Loop protection is also available to prevent the generation of broadcast storm when a dumb switch is inserted in a closed loop connection.
Support PXE to verify switch firmware with the latest or certain version
The switch can check its firmware version during booting time via PXE protocol. If switch finds any newer
version, it will upload automatically.
Optional L3Lite to be upgradable
Lantech OS3 and OS4 are optional upgradable to L3 Lite for future expansion. The optional L3Lite includes
editable routing table, VRRP, Router-on-a-stick, Inter- VLAN routing.
DHCP option 82 & Port based, Mac based DHCP, Option66, DHCP Snooping, IPv6 DHCP
server
DHCP server can assign dedicated IP address by MAC or by port (Port based for single switch) , it also can
assign IP address by port for multiple switches with single DHCP option82 server. DHCP Snooping is
supported. For the ending device which need to download file from TFTP server, DHCP Option66 server can
offer IP address of TFTP server to DHCP client. Basic IPv6 DHCP service can be supported.
User friendly GUI, Auto topology drawing, FX dB value
The user friendly UI, innovative auto topology drawing and topology demo makes I(P)GS-6300-2P much easier
to get hands-on. The I(P)GS-6300-2P supports DMI interface that can correspond with DDM SFPs (Digital
diagnostic monitor) to display the five parameters in Lantech’s UI, including optical output power, input
power, temperature, laser bias current and transceiver supply voltage***. The TX power/RX power raw data
is automatically converted to dB values for installer, making it easier to calculate the fiber distance.
The complete CLI enables professional engineer to configure setting by command line.
Enhanced G.8032 ring, 8 MSTI MSTP; MRP ring
Lantech I(P)GS-6300-2P features enhanced G.8032 ring which can be self-healed in less than 20ms for single
ring topology protection covering multicast packets. It also supports various ring topologies that covers
enhanced ring and basic ring by easy setup than others. It supports MSTP that allows RSTP over VLAN for
redundant links with 8 MSTI. MRP (Media Redundancy Protocol) can be supported for industrial automation
networks.
QinQ, QoS and GVRP supported
It supports the QinQ, QoS, GVRP for large VLAN segmentation.
802.1X security by MAC address
MAC-based port authentication is an alternative approach to 802.1x for authenticating hosts connected to a
port. By authenticating based on the host's source MAC address, the host is not required to run a user for
the 802.1x protocol. The RADIUS server that performs the authentication will inform the switch if this MAC
can be registered in the MAC address table of switch.
IGMPv3, GMRP, router port, MLD Snooping, static multicast forwarding and multicast Ring
protection
The unique multicast protection under enhanced G.8032 ring can offer immediate self-recovery instead of
waiting for IGMP table timeout. It also supports IGMPv3, GMRP, router port, MLD snooping and static
multicast forwarding binding by ports for video surveillance application.
Enhanced Storm Control
Storm control prevents traffic on a LAN from being disrupted by a broadcast, multicast, or unicast storm
on one of the physical interfaces and the detection is more precise and reaction is more efficient.
Editable configuration file; USB port for upload/download configuration
The configuration file of Lantech I(P)GS-6300-2P can be exported and edited with word processor for the
other switches configuration with ease. The factory reset button can restore the setting back to factory
default and built-in watchdog design can automatically reboot the switch when CPU is found dead.
I(P)GS-6300-2P also supports dual image firmware function.
The built-in USB slot can upload/download the firmware through USB dongle for switch replacement.
Event log & message; 2 DI + 2DO
In case of event, the I(P)GS-6300-2P is able to send an email to pre-defined addresses as well as SNMP
Traps out immediately. It provides 2DI and 2DO. When disconnection of the specific port was detected; DO
will activate the signal LED to alarm. DI can integrate the sensors for events and DO will trigger the
alarm while sending alert information to IP network with email and traps.
Enhanced Environmental monitoring for Ethernet switch inside information
The enhanced environmental monitoring can detect the switch's overall temperature, actual input voltage
and current. It also can send the SNMP traps and email** when abnormal.
Dual power DC/LDC/HV/AC inputs and dedicated PoE power source input
Lantech I(P)GS-6300-2P chassis and modules are designed for easy maintenance and installation; It also
supports dual DC/LDC power supplies (DC12~48V/ isolated 36~75VDC), dual HV (isolated 85~264VAC/120~370VDC)
or dual AC(85~264VAC) input to increase the network reliability. It has independent PoE power source input
by terminal block for connecting DC 48V PoE power source. (IPGS-6300-2P)
Industrial hardened design with high EFT/SURGE and ESD CONTACT protection
Lantech I(P)GS-6300-2P features high reliability and robustness coping with extensive EMI/RFI phenomenon,
environmental vibration and shocks usually found in factory, substation, steel automation, aviation,
mining and process control. Featured with relay contact alarm function, the I(P)GS-6300-2P is able to
connect with alarm system in case of power failure or port disconnection. The I(P)GS-6300-2P also provides
2000V EFT/SURGE and 6000V ESD CONTACT protection, which can reduce unstable situation caused by power line
and Ethernet.
It is the best solution for Automation, transportation, surveillance, Wireless backhaul, Semi-conductor factory applications. The -E model can be used in extreme environments with an operating temperature range of -40°C to 75°C.
IEEE Standards |
IEEE 802.3 10Base-T Ethernet |
Switch Architecture |
Back-plane (Switching Fabric): 128Gbps |
Mac Address |
16K MAC address table |
Jumbo frame |
10KB |
Connectors |
Max. 24 10/100/1000T RJ-45 with auto MDI/MDI-X function |
Network Cable |
10Base-T: 2-pair UTP/STP Cat. 3, 4, 5/ 5E/ 6 cable |
Optical Cable |
1Gbps: |
LED |
Per unit: Power 1 (Green), Power 2 (Green), FAULT (Red); RM(Green) |
DI/DO |
2 Digital Input (DI) : |
Operating Humidity |
5% ~ 95% (Non-condensing) |
Operating Temperature |
-20°C~60°C / -4°F~140°F (Standard model) |
Storage Temperature |
-40°C~85°C / -40°F~185°F |
Power Supply |
One+ one** VAC/VDC input isolated 3000V 85V~264VAC/120~370VDC(HV model) |
PoE Budget |
720W (from separate PoE power supply) |
PoE pin assignment |
RJ-45 port # 1~#24 support IEEE 802.3at/af End-point, Alternative A mode.(IPGS-6300-2P &
PoE modules) |
Power Consumption |
30W |
Case Dimension |
Metal case. IP-30 |
Weight |
2.9 kgs |
Installation |
Rackmount Design |
EMI & EMS |
FCC, |
Stability Testing |
IEC60068-2-32 (Free fall), IEC60068-2-27 (Shock), |
MTBF |
830589 hours (standards IEC 62380) |
Warranty |
5 years |
Management |
SNMP v1 v2c, v3/ Web/Telnet/CLI |
SNMP MIB |
RFC 1213 MIBII |
ITU G.8032 |
Support ITU G.8032 for Ring protection in less than 20ms for self-heal recovery (single ring
enhanced mode) |
PoE Management |
PoE Detection to check if PD hangs then restart the PD(IPGS-6300-2P) |
Per Port PoE Status |
On/ Off, voltage, current, watts, temperature(IPGS-6300-2P) |
User friendly UI |
|
Port Trunk with LACP |
LACP Port Trunk: 8 Trunk groups |
LLDP |
Supports LLDP to allow switch to advise its identification and capability on the LAN |
CDP |
Cisco Discovery Protocol for topology mapping |
Enhanced Environmental Monitoring |
System status for actual input voltage, current, total power load and ambient temperature to be shown in GUI and sent alerting if any abnormal status |
VLAN |
Port Based VLAN |
Spanning Tree |
Supports IEEE802.1d Spanning Tree and IEEE802.1w Rapid Spanning Tree, IEEE802.1s Multiple Spanning Tree 8 MSTI |
Quality of Service |
The quality of service determined by port, Tag and IPv4 Type of service, IPv4 Differentiated Services Code Points - DSCP |
Class of Service |
Support IEEE802.1p class of service, per port provides 8 priority queues |
Remote Admin |
Supports 10 IP addresses that have permission to access the switch management and to prevent unauthorized intruder |
Login Security |
Supports IEEE802.1X Authentication/RADIUS |
Port Mirror |
Support 3 mirroring types: “RX, TX and Both packet” |
Network Security |
Support 10 IP addresses that have permission to access the switch management and to prevent
unauthorized intruder. |
IGMP |
Support IGMP snooping v1,v2,v3; Supports IGMP static route; 1024 multicast groups; IGMP router port ; IGMP query; GMRP |
MLD Snooping |
Support IPv6 Multicast stream |
Static multicast forwarding |
Static multicast forwarding forward reversed IGMP flow with multicast packets binding with ports for IP surveillance application |
Bandwidth Control |
Support ingress packet filter and egress packet limit. |
Flow Control |
Supports Flow Control for Full-duplex and Back Pressure for Half-duplex |
System Log |
Supports System log record and remote system log server |
SMTP** |
Supports SMTP** Server and 8 e-mail accounts for receiving event alert |
Relay Alarm |
Provides one relay output for port breakdown, power fail and alarm. |
Protection |
|
SNMP Trap |
Up to 10 trap stations; trap types including:
|
PXE |
PXE to verify switch firmware with the latest or certain version |
DHCP |
Provide DHCP Client/ DHCP Server/DHCP Option 82/Port based DHCP; DHCP Snooping; DHCP Option 66; basic IPv6 DHCP server |
Mac based DHCP Server |
Assign IP address by Mac that can include dumb switch in DHCP network |
Optional L3Lite/L3* |
Lantech OS3 is optional upgradable to L3 Lite/L3* for future expansion. The optional L3Lite includes editable routing table, VRRP, Router-on-a-stick, Inter- VLAN routing. |
DNS |
Provide DNS client feature and can set Primary and Secondary DNS server |
SNTP |
Supports SNTP to synchronize system clock in Internet |
Firmware Update |
Supports TFTP firmware update, TFTP backup and restore; HTTP firmware upgrade |
Enhanced Storm Control |
prevents traffic on a LAN from being disrupted by a broadcast, multicast, or unicast storm on one of the physical interfaces |
Configuration |
Supports text configuration file for system quick installation; Support factory reset button to restore all settings back to factory default; USB for mass backup, editing configuration and upgrade |
Diagnostic |
Support Ping, ARP table and DDM information |
Dual Image Firmware |
Support dual image firmware function |
P/N | Model name | Description |
---|---|---|
8380-208 | IGS-6300-2P-HV | 4 Modular Slots L2 plus Industrial 10G Uplink Ethernet Switch Chassis; Built-in 1x isolated AC/DC 85~264VAC/120V~370VDC power conversion + 1x additional power socket; -20°C to 60°C |
8380-2081 | IGS-6300-2P-HV-E | 4 Modular Slots L2 plus Industrial 10G Uplink Ethernet Switch Chassis; Built-in 1x isolated AC/DC 85~264VAC/120V~370VDC power conversion + 1x additional power socket; -40°C to 75°C |
8380-209 | IGS-6300-2P-LDC | 4 Modular Slots L2 plus Industrial 10G Uplink Ethernet Switch Chassis; Built-in 1x isolated DC 36~75VDC power supply + 1x additional power socket; -20°C to 60°C |
8380-2091 | IGS-6300-2P-LDC-E | 4 Modular Slots L2 plus Industrial 10G Uplink Ethernet Switch Chassis; Built-in 1x isolated DC 36~75VDC power supply + 1x additional power socket; -40°C to 75°C |
8380-202 | IGS-6300-2P-AC | 4 Modular Slots L2 plus Industrial 10G Uplink Ethernet Switch Chassis; Built-in 1x AC85~264VAC IEC320 power conversion + 1x additional power socket; -20°C to 60°C |
8380-203 | IGS-6300-2P-AC-E | 4 Modular Slots L2 plus Industrial 10G Uplink Ethernet Switch Chassis; Built-in 1x AC85~264VAC IEC320 power conversion + 1x additional power socket; -40°C to 75°C |
8380-205 | IGS-6300-2P-DC | 4 Modular Slots L2 plus Industrial 10G Uplink Ethernet Switch Chassis; Built-in 1x DC 12~60VDC power module + 1x additional power socket; -20°C to 60°C |
8380-206 | IGS-6300-2P-DC-E | 4 Modular Slots L2 plus Industrial 10G Uplink Ethernet Switch Chassis; Built-in 1x DC 12~60VDC power module + 1x additional power socket; -40°C to 75°C |
8380-210 | IPGS-6300-2P-HV | 4 Modular Slots L2 plus Industrial 10G PoE Ethernet Switch Chassis; Built-in 1x isolated AC/DC 85~264VAC/120V~370VDC power conversion + 1x additional power socket + 1x 48VDC PoE power input; -20°C to 60°C |
8380-2101 | IPGS-6300-2P-HV-E | 4 Modular Slots L2 plus Industrial 10G PoE Ethernet Switch Chassis; Built-in 1x isolated AC/DC 85~264VAC/120V~370VDC power conversion + 1x additional power socket + 1x 48VDC PoE power input; -40°C to 75°C |
8380-211 | IPGS-6300-2P-LDC | 4 Modular Slots L2 plus Industrial 10G PoE Ethernet Switch Chassis; Built-in 1x isolated DC 36~75VDC power supply + 1x additional power socket + 1x 48VDC PoE power input; -20°C to 60°C |
8380-2111 | IPGS-6300-2P-LDC-E | 4 Modular Slots L2 plus Industrial 10G PoE Ethernet Switch Chassis; Built-in 1x isolated DC 36~75VDC power supply + 1x additional power socket + 1x 48VDC PoE power input; -40°C to 75°C |
8380-204 | IPGS-6300-2P-AC | 4 Modular Slots L2 plus Industrial 10G PoE Ethernet Switch Chassis; Built-in 1x AC85~264VAC IEC320 power conversion + 1x additional power socket + 1x 48VDC PoE power input; -20°C to 60°C |
8380-2041 | IPGS-6300-2P-AC-E | 4 Modular Slots L2 plus Industrial 10G PoE Ethernet Switch Chassis; Built-in 1x AC85~264VAC IEC320 power conversion + 1x additional power socket + 1x 48VDC PoE power input; -40°C to 75°C |
8380-207 | IPGS-6300-2P-DC | 4 Modular Slots L2 plus Industrial 10G PoE Ethernet Switch Chassis; Built-in 1x DC 12~60VDC power module + 1x additional power socket + 1x 48VDC PoE power input; -20°C to 60°C |
8380-2071 | IPGS-6300-2P-DC-E | 4 Modular Slots L2 plus Industrial 10G PoE Ethernet Switch Chassis; Built-in 1x DC 12~60VDC power module + 1x additional power socket + 1x 48VDC PoE power input; -40°C to 75°C |
P/N | Model name | Discription |
---|---|---|
8380-123 | 8x GIGA T Module | 8x 10/100/1000T Module; -40°C to 75°C |
8380-124 | 8x GIGA T-PoE at/af Module | 8x 10/100/1000T PoE at/af Module; -40°C to 75°C |
8380-125 | 8x SFP Module | 8x Dual Speed SFP module for 100M SFP or Gigabit SFP; -40°C to 75°C |
8380-126 | 4x 10G SFP Module | 4x 1G/2.5G/10G SFP Module for slot 4; -40°C to 75°C |
8380-127 | 2 100M/1G/10G Copper + 2 100M/1G/2.5G/10G SFP+ Module | 2x 100M/1G/10G Copper + 2 100M/1G/2.5G/10G SFP+ Module for slot 4 ; -40°C to 75°C |
P/N | Model name | Description |
---|---|---|
9000-114 | OS3 – L3L | OS3 software platform with Layer 3 Lite functions (please check Lantech software data sheet for details) |
9000-116 | OS3 – L3* | OS3 software platform with Layer 3 functions incl. L3L (please check Lantech software data sheet for details) |
Model name | Description |
---|---|
EOTH000705 | Isolation Power 85-264VAC, 120-370VDC 1.5A , 47-63HZ![]() |
EOTH000702 | Isolation Power 36-75VDC, 2.5A![]() |
EOTH000706 | Power 85-264VAC IEC320 socket, 1.5A , 47-63HZ![]() |
EOTH000704 | Power Input Module 12-60VDC, 2.5A![]() |
Model name | Description |
---|---|
NDR-480 Series | 480W Single Output Industrial Din Rail Power; 90-264VAC / 127-370VDC Input Range; Cooling by free air convection; RoHS2 ; Operating Temp. -20°C~70°C (ambient, derating each output at 2.5% per degree from 50°C ~ 70°C) |
NDR-240 Series | 240W Single Output Industrial Din Rail Power; 90-264VAC / 127-370VDC Input Range; Cooling by free air convection; RoHS2 ; Operating Temp. -20°C~70°C (ambient, derating each output at 2.5% per degree from 50°C ~ 70°C) |
NDR-120 Series | 120W Single Output Industrial Din Rail Power; 90-264VAC / 127-370VDC Input Range; Cooling by free air convection; RoHS2 ; Operating Temp. -20°C~70°C (ambient, derating each output at 2.5% per degree from 50°C ~ 70°C; For 115VAC, please refer to derating curve on NDR-120 Series datasheet) |
NDR-75 Series | 75W Single Output Industrial Din Rail Power; 90-264VAC / 127-370VDC Input Range; Cooling by free air convection; RoHS2 ; Operating Temp. -20°C~70°C (ambient, derating each output at 2.5% per degree from 50°C ~ 70°C; For 115VAC, please refer to derating curve on NDR-120 Series datasheet) |
Model name | Description | Model name | Description |
---|---|---|---|
8330-162-V1 | MINI GBIC 1000SX (LC/0.5km) Transceiver | 8330-183-V1 | LTSFP-1000BX-60KM Transceiver (WDM 1550) |
8330-163-V1 | MINI GBIC 1000SX2 (LC/2km) Transceiver | 8330-184-V1 | LTSFP-1000BX-80KM Transceiver (WDM 1490) |
8330-165-V1 | MINI GBIC 1000LX (LC/10km) Transceiver | 8330-185-V1 | LTSFP-1000BX-80KM Transceiver (WDM 1550) |
8340-0591-V1 | MINI GBIC 1000LHX (LC/40km) Transceiver | 8330-262D-V1 | MINI GBIC 2.5G 850nm VCSEL (LC/0.3km) Transceiver |
8330-166-V1 | MINI GBIC 1000XD (LC/50km) Transceiver | 8330-263D-V1 | MINI GBIC 2.5G 1310nm FP (LC/2km) Transceiver |
8330-169-V1 | MINI GBIC 1000XD (LC/60km) Transceiver | 8330-265D-V1 | MINI GBIC 2.5G 1310nm DFB (LC/15km) Transceiver |
8330-167-V1 | MINI GBIC 1000ZX (LC/80km) Transceiver | 8330-193D-V1 | 10G Base SFP+ SR, Multi-mode (LC/300m) Transceiver |
8330-170-V1 | MINI GBIC 1000EZX (120km) Transceiver | 8330-194D-V1 | 10G Base SFP+ LR, Single-mode (LC/10km) Transceiver |
8330-168-V1 | MINI GBIC 1000T (100m) Transceiver | 8330-209D-V110G Base SFP+ , Single-mode(10km) Transceiver (WDM 1270) |
|
8330-188-V1 | LTSFP-1000BX-10KM Transceiver (WDM 1310) | 8330-210D-V1 | 10G Base SFP+ , Single-mode(10km) Transceiver (WDM 1330) |
8330-189-V1 | LTSFP-1000BX-10KM Transceiver (WDM 1550) | 8330-200D-V1 | 10G Base SFP+ , Single-mode(20km) Transceiver (WDM 1270) |
8330-186-V1 | LTSFP-1000BX-20KM Transceiver (WDM 1310) | 8330-201D-V1 | 10G Base SFP+ , Single-mode(20km) Transceiver (WDM 1330) |
8330-187-V1 | LTSFP-1000BX-20KM Transceiver (WDM 1550) | 8330-202D-V1 | 10G Base SFP+ , Single-mode(40km) Transceiver (WDM 1270) |
8330-180-V1 | LTSFP-1000BX-40KM Transceiver (WDM 1310) | 8330-203D-V1 | 10G Base SFP+ , Single-mode(40km) Transceiver (WDM 1330) |
8330-182-V1 | LTSFP-1000BX-40KM Transceiver (WDM 1550) | 8330-206-V1 | 10G/5G/2.5G/1000Base-T SFP, 3.3V,30m (10G) 50m (2.5G/5G) 100m (1G); -10~70°C (only used from 18V~56VDC power input, maximum two ports) |
8330-181-V1 | LTSFP-1000BX-60KM Transceiver (WDM 1310) | All SFP ended with D are with Diagnostic function |
2020 © Lantech Communications Australia Pty Ltd. ALL Rights Reserved. Privacy Policy | Terms of Service